Assessment and Management of Prosthetic Valve Mismatch
Definition and Diagnostic Criteria
- The American College of Cardiology defines patient-prosthesis mismatch (PPM) as a condition where the effective orifice area of a normally functioning prosthetic valve is too small relative to the patient's body size and metabolic demands, and it should be suspected in patients with persistent cardiac symptoms after aortic valve replacement who have high prosthetic valve velocity or gradient (mean gradient >20 mmHg) with a small calculated indexed effective orifice area (iEOA ≤0.85 cm²/m²) 1, 2, 3
- PPM is classified into moderate (iEOA 0.65-0.85 cm²/m²) and severe (iEOA <0.65 cm²/m²) forms, with the American College of Cardiology recommending careful evaluation and management of patients with severe PPM 1, 2, 3
Clinical Assessment Algorithm
- The American Heart Association recommends a step-wise approach to diagnose PPM, starting with transthoracic echocardiography (TTE) with 2D and Doppler assessment to measure peak velocity, mean gradient, and calculate effective orifice area by continuity equation, followed by transesophageal echocardiography (TEE) if TTE is inadequate or results are discordant 4, 5
- The European Society of Cardiology suggests measuring left ventricular function, hypertrophy regression, and other valve disease to assess the clinical impact of PPM 6
Clinical Impact Assessment
- Severe PPM is associated with high transvalvular gradients, persistent left ventricular hypertrophy, and increased rate of cardiac events, according to the American College of Cardiology 1, 2, 3
- The American College of Cardiology recommends that patients with severe PPM should be carefully evaluated for re-intervention, considering symptoms, hemodynamic abnormalities, ventricular function, and surgical risk assessment 1, 2, 3
Management Approach
- The American College of Cardiology recommends medical management for patients with postoperative LV systolic dysfunction, including standard medical therapy for systolic heart failure, continued indefinitely even if systolic function improves 4, 5
- Repeat valve replacement is indicated for severe symptomatic prosthetic valve stenosis, but for PPM specifically, re-intervention should only be considered if symptoms persist despite optimal medical therapy, severe PPM is confirmed, and patient has reduced LVEF or significant functional limitation 1, 2, 3
- The American College of Cardiology suggests that the decision to re-intervene requires careful hemodynamic evaluation based on hemodynamic abnormalities, symptom severity, ventricular function, and surgical risk assessment 4, 5
Prevention Strategy
- The American College of Cardiology recommends prospective planning at the time of initial valve replacement to prevent PPM, including calculating predicted iEOA using the normal reference EOA of the selected prosthesis and patient's body surface area, choosing valve prosthesis that will provide adequate iEOA (>0.85 cm²/m²), and considering annular enlargement procedures if needed 1, 2, 3
Intraoperative Assessment of Patient-Prosthesis Mismatch
Preoperative Planning to Prevent PPM
- The American College of Cardiology recommends targeting an indexed effective orifice area (iEOA) >0.85 cm²/m² to avoid clinically significant patient-prosthesis mismatch (PPM) 7
Intraoperative Prevention Strategies
- The American College of Cardiology suggests considering alternative strategies, such as selecting a newer generation prosthetic valve or performing annular enlargement procedures, if the calculated iEOA will be ≤0.85 cm²/m² 7
- Transcatheter aortic valve replacement (TAVR) may be considered instead of surgical aortic valve replacement (AVR) in patients with small aortic annulus, as TAVR has thinner stents that minimize obstruction and reduce PPM incidence 8, 9
Immediate Post-Implantation Assessment
- The American College of Cardiology recommends measuring mean transvalvular gradient, which should typically be <10 mmHg for aortic prostheses, after valve deployment 8, 9
- Effective orifice area should be calculated using the continuity equation, and indexed EOA should be assessed by dividing EOA by body surface area 8, 9, 10
Distinguishing PPM from Prosthetic Valve Stenosis
- Prosthetic valve stenosis can be distinguished from PPM by high gradients with reduced EOA compared to normal reference values, and abnormal leaflet morphology or restricted mobility, according to the European Heart Journal 10
Common Pitfalls
- Bileaflet mechanical valves may show high velocities due to complex flow patterns and pressure recovery, which should not be mistaken for PPM or stenosis, as noted by the American College of Cardiology 7
- Failure to use prosthesis-specific reference values when calculating EOA can lead to misdiagnosis, and inadequate LVOT measurements can compromise EOA calculation accuracy, according to the European Heart Journal 10