Praxis Medical Insights

Est. 2024 • Clinical Guidelines Distilled

Made possible by volunteer editors from the University of Calgary & University of Alberta

Last Updated: 10/3/2025

External Scleral and Ocular Landmarks for Internal Structures

Key External Anatomical Landmarks

  • The external scleral landmarks for locating internal ocular structures are based on axial length-related measurements, with the electronics case and implant positioning determined by precise external fixation tables that correlate surface anatomy to underlying macular and retinal structures 1
  • The four rectus muscles serve as primary external reference points for surgical planning and device positioning 1
  • These muscles are isolated during 360° conjunctival peritomy to establish orientation for deeper structure localization 1
  • The superotemporal quadrant is the standard external reference zone for positioning devices relative to internal structures 1
  • Precise measurements from this external location correlate with optimal electrode array placement over the macula internally 1
  • Axial length-related tables provide specific measurements from external scleral fixation points to ensure accurate positioning over internal retinal structures 1

Internal Structure Correlation

  • The pars plana serves as the external landmark for accessing the vitreous cavity 1
  • A 5.2 mm sclerotomy through the pars plana allows insertion of arrays while avoiding damage to internal structures like the ciliary body 1
  • The sclerotomy should be directed perpendicular to the sclera to prevent ciliary body detachment, demonstrating the critical relationship between external approach angle and internal structure preservation 1

Clinical Implications

  • External fixation measurements must be precisely calculated based on axial length to ensure optimal internal positioning, as this is identified as a critical component affecting electrode array placement over the macula 1
  • Sclerotomy construction requires attention to wound geometry—straight incisions perpendicular to sclera prevent internal complications 1
  • Long scleral passes with mattress sutures increase vector forces for wound closure, preventing hypotony from inadequate sclerotomy closure 1

Common Pitfalls

  • Assuming small amounts of wound oozing will resolve spontaneously—this should never be assumed and requires thorough checking for leakage 1
  • Using curved or chevron-shaped sclerotomies instead of straight incisions, which causes cable and wound puckering 1
  • Failing to account for axial length variations when translating external measurements to internal structure locations 1
  • The scleral spur represents a critical anatomical landmark visible on both external examination (via gonioscopy) and internal imaging 2