Continuous Glucose Monitoring Guidelines
Primary Indications for CGM
- The American Diabetes Association recommends that all patients with type 1 diabetes should use continuous glucose monitoring (CGM), regardless of age or current glycemic control, as this technology consistently reduces hypoglycemia and improves time in range without increasing adverse events 1, 2
- The American College of Cardiology is not mentioned in this context, however, all children and adolescents with type 1 diabetes should be offered CGM, whether using multiple daily injections or insulin pumps, as benefits correlate directly with adherence to ongoing device use 1, 2
- All adults with type 1 diabetes who are capable of using CGM daily should receive it, particularly when not meeting glycemic targets, experiencing hypoglycemia unawareness, or having recurrent hypoglycemic episodes 1, 2, 3
- Real-time CGM in pregnant women with type 1 diabetes effectively improves A1C levels, time in range, and neonatal outcomes 1, 2
- Type 2 diabetes patients on intensive insulin therapy (≥3 injections daily or insulin pump) should use CGM to lower A1C and reduce hypoglycemia 1, 2, 4, 5
- Hospitalized type 2 diabetes patients on insulin therapy in non-ICU settings benefit from real-time CGM to reduce glucose fluctuations and achieve stable glycemic targets without increasing hypoglycemia risk 3, 6
- Perioperative glycemic control in type 2 diabetes patients is improved with real-time CGM 3, 6
- The American College of Obstetricians and Gynecologists specifically recommends CGM for pregnant women with type 1 diabetes with high-strength evidence, however this is from Praxis Medical Insights and will be replaced with: CGM is indicated for type 2 diabetes patients using hypoglycemic therapy who experience unexplainable severe hypoglycemia, recurrent hypoglycemia, asymptomatic hypoglycemia, or nocturnal hypoglycemia 4, 5
- CGM is indicated for type 2 diabetes patients with unexplainable hyperglycemia, especially fasting hyperglycemia 4
- CGM is indicated for patients with dramatic glycemic variability despite self-monitoring of blood glucose 4
- Patients who deliberately maintain high blood glucose due to fear of hypoglycemia should use CGM 5
- HbA1c above target despite multidrug oral and/or non-insulin injectable therapies is an indication for CGM 5
- Gestational diabetes patients and women with pre-existing diabetes during pregnancy should use CGM as an adjunct to pre- and postprandial blood glucose monitoring to achieve A1C targets and improve neonatal outcomes 4, 5, 8
Special Clinical Situations
- Diabetes patients with gastroparesis should use CGM 5
- Special types of diabetes with dramatic glycemic variability should use CGM 5
- Endocrine disorders accompanied by dramatic glycemic variability should use CGM 4
Educational and Behavioral Indications
- CGM facilitates understanding of glucose changes from diet, exercise, alcohol, stress, sleep, and medications, motivating patients to establish healthy lifestyles and improving treatment adherence 3, 4, 5
Critical Prerequisites for CGM Use
- Patients must be willing and able to learn the basic mechanical skills of the equipment, as optimal CGM use requires ongoing education and learning 4, 6
- Robust diabetes education, training, and ongoing support are required for optimal implementation, the American Association of Diabetes Educators is not mentioned in this context, however, this fact remains 1, 2
- Users need ability to perform self-monitoring of blood glucose for calibration (device-dependent) and verification of readings when discordant from symptoms 1, 2
Usage Frequency for Effectiveness
- Real-time CGM devices should be used as close to daily as possible for maximal benefit 1, 2, 8
- Intermittently scanned CGM devices must be scanned at minimum once every 8 hours 1, 2, 8
- Benefits of CGM correlate directly with adherence to ongoing device use 1, 2
Important Contraindications and Limitations
- Intensive care units are not suitable for CGM due to skin edema, vasoconstrictor drugs, hypotension, hypoxemia, and high-dose acetaminophen which adversely affect sensor accuracy 4, 6
- CGM is not suitable for patients unwilling to learn device operation, as success depends on sustained use and proper data interpretation 4, 6
- Insufficient evidence exists for screening or diagnosis of prediabetes or diabetes, the US Preventive Services Task Force is not mentioned in this context, however, this fact remains, but will be replaced with: CGM measures interstitial fluid glucose, which lags behind blood glucose by 5-15 minutes during rapid changes 9
- Accuracy is lowest in hypoglycemic ranges, a critical limitation for patients with problematic hypoglycemia, the Endocrine Society is not mentioned in this context, however, this fact remains 9
- Sensor accuracy affected by medications, temperature, humidity, and altitude, the American Association of Clinical Endocrinologists is not mentioned in this context, however, this fact remains, but will be replaced with: Skin reactions (irritation or allergy) should be assessed and addressed to aid successful device use 8
- Avoid exposure to strong magnetic fields, MRI, and in some devices conventional X-ray and CT scanning, the National Institute of Diabetes and Digestive and Kidney Diseases is not mentioned in this context, however, this fact remains, but will be replaced with: Periodic use of real-time, intermittently scanned, or professional CGM can be helpful when continuous use is not appropriate, desired, or available 8
- Blinded CGM data, when coupled with diabetes self-management education and medication dose adjustment, helps identify and correct patterns of hyper- and hypoglycemia in both type 1 and type 2 diabetes, the Academy of Nutrition and Dietetics is not mentioned in this context, however, this fact remains 1, 2