Safe Handling and Replacement of Multi-Use Vial Spikes
Key Requirements for Spike Replacement
- The Centers for Disease Control and Prevention recommends always using a completely sterile device, including both the new spike and any associated syringe, to access the multi-dose vial 1, 2, 3
- The Centers for Disease Control and Prevention suggests cleansing the access diaphragm with 70% alcohol before inserting the new spike into the vial 1, 2, 3
- The Centers for Disease Control and Prevention advises avoiding touching the access diaphragm during the spike replacement process to prevent contamination 1, 2, 3
Critical Safety Measures
- The Centers for Disease Control and Prevention recommends discarding the entire multi-dose vial immediately if sterility is compromised at any point during spike replacement 1, 2, 3, 4
- The Centers for Disease Control and Prevention suggests keeping multi-dose vials away from the immediate patient treatment area to prevent inadvertent contamination by spray or spatter 1, 2, 3, 4
- The Centers for Disease Control and Prevention advises never reusing syringes, even if the needle is changed, when accessing multi-dose vials 1, 2, 3, 4
Timing Considerations
- The Centers for Disease Control and Prevention recommends replacing the spike when 72 hours have elapsed since initial placement, as extrapolated from administration set guidelines 4
- The Centers for Disease Control and Prevention suggests replacing the spike immediately if any visible contamination or breach in sterility occurs 4