Margins for CTV and PTV from GTV for SBRT to Paraortic Lymph Nodes
GTV to CTV Margin Recommendations
- A 5 mm expansion from GTV to CTV is recommended for lymph nodes, based on European Organisation for Research and Treatment of Cancer (EORTC) guidelines 1, 2, 3
- This margin accounts for microscopic disease extension beyond the visible tumor 2
- In some SBRT protocols, no CTV margin has been used, but this approach deviates from International Commission on Radiation Units and Measurements (ICRU) guidelines 1
CTV to PTV Margin Recommendations
- For non-MRI guided treatments, historical series used generic CTV-PTV margins ranging from 10-15 mm 1, 3
- With modern image guidance and motion management techniques, these margins can be reduced 1
- The specific CTV-PTV margin should account for: method of immobilization 1, assessment of tumor motion 1, methods for on-treatment setup verification/repositioning (e.g., cone beam CT) 1, and institution-specific setup uncertainties 2
Treatment Planning Considerations
- When using 4D-CT scans, an internal target volume (ITV) approach can be used to account for respiratory motion 1
- Dose calculations should be performed on the CT reconstruction phase representing the time-averaged mean position of the tumor 1
- When gating or tracking techniques are used, the CTV-PTV margin should account for the gating window 1
- Type B dose calculation algorithms should be used for treatment planning 1, 2
- Manual PTV adjustments should not be performed 1