TEVAR Sizing Criteria
Stent-Graft Diameter Oversizing
- The European Society of Cardiology recommends oversizing the stent-graft by 10-15% relative to the reference aortic diameter measured at the proximal and distal landing zones for thoracic aortic aneurysms 1, 2
- Oversizing the stent-graft by 10-15% provides optimal seal while minimizing complications such as endoleak and stent-graft induced new entry (SINE) 1
- For type B aortic dissection, the European Society of Cardiology recommends applying minimal to no oversizing (0-10%) to cover the proximal entry tear and induce false lumen thrombosis without excessive radial force 3, 2
Landing Zone Requirements
- A minimum landing zone length of 20 mm is required both proximally and distally for safe deployment and durable fixation, as recommended by the European Society of Cardiology 4, 1
- The proximal landing zone should not exceed 40 mm in diameter for standard TEVAR devices, according to the European Society of Cardiology 2
Pre-Procedural Measurement Technique
- The European Society of Cardiology recommends obtaining contrast-enhanced CT with ≤3 mm slice thickness of the entire aorta from supra-aortic branches to femoral arteries for pre-procedural measurement 2
- The American College of Radiology suggests using ECG-gated CT for the ascending aorta to account for cardiac motion, which can cause 5-10% variation in diameter between systole and diastole 5, 6
Anatomic Assessment Beyond Sizing
- The American College of Radiology recommends assessing aortic tortuosity at the proximal landing zone, as increased tortuosity index significantly predicts type III endoleak, stroke, and all-cause mortality after TEVAR 5, 6
- The European Society of Cardiology suggests identifying the relationship to critical branch vessels (left subclavian artery, intercostal arteries supplying spinal cord) and measuring distances between arch vessels and alignment if arch coverage is planned 2, 5, 6
Intraoperative Considerations
- The European Society of Cardiology recommends reducing systolic blood pressure to <80 mmHg during stent-graft deployment to prevent downstream displacement 3, 2
- The European Society of Cardiology suggests considering intraoperative IVUS or TOE for real-time diameter verification, particularly in hemodynamically unstable patients or when navigating the true lumen in dissections 3, 7