Proper Technique for Inserting a 14G Cannula

Preparation

  • The American Journal of Kidney Diseases recommends performing a complete physical assessment of the access site and documenting findings 3
  • The American Journal of Kidney Diseases suggests locating and palpating the cannulation sites prior to skin preparation 1
  • The American Journal of Kidney Diseases advises washing the access site using an antibacterial soap or scrub (e.g., 2% chlorhexidine) and water 1
  • The American Journal of Kidney Diseases recommends cleansing the skin by applying 70% alcohol and/or 10% povidone iodine using a circular rubbing motion 1
  • Alcohol should be applied in a rubbing motion for 1 minute immediately prior to cannulation, as recommended by the American Journal of Kidney Diseases 1
  • If using povidone iodine, the American Journal of Kidney Diseases suggests allowing 2-3 minutes for full bacteriostatic action and letting it dry before cannulation 1

Insertion Technique

  • The American Journal of Kidney Diseases recommends putting on clean gloves before cannulation 1
  • After skin preparation, the American Journal of Kidney Diseases suggests pulling the skin taut in the opposite direction of needle insertion to compress peripheral nerve endings 2
  • The American Journal of Kidney Diseases advises grasping the needle wings and removing the tip protector 3
  • The American Journal of Kidney Diseases recommends aligning the needle cannula with the bevel facing up over the cannulation site 3
  • For AV grafts, the American Journal of Kidney Diseases suggests using approximately a 45-degree angle of insertion 2
  • For AV fistulae, the American Journal of Kidney Diseases recommends using approximately a 25-degree angle of insertion 2
  • Once the vessel has been penetrated, the American Journal of Kidney Diseases suggests advancing the needle slowly with cutting edge facing top of vessel without rotating 1
  • The American Journal of Kidney Diseases recommends immediately rotating the axis of the needle 180 degrees and advancing slowly with cutting edge facing bottom of vessel 1
  • The American Journal of Kidney Diseases advises advancing the needle to desired position, then rotating the axis 180 degrees 2
  • A flashback of blood indicates the needle is in the access, according to the American Journal of Kidney Diseases 3
  • The American Journal of Kidney Diseases recommends lowering the angle of insertion and continuing to advance the needle until appropriately positioned within the vessel 3
  • The American Journal of Kidney Diseases suggests securely taping the needle at the same angle or similar to the angle of insertion 2

Post-Insertion Care

  • When removing the needle, the American Journal of Kidney Diseases recommends using the same or similar angle as insertion 2
  • The American Journal of Kidney Diseases advises never applying pressure before the needle is completely out to avoid trauma to the vessel 2

Common Pitfalls and How to Avoid Them

  • Pressing the needle shaft flat against the skin can move the needle tip from the desired position within the vessel lumen, according to the American Journal of Kidney Diseases 2
  • The American Journal of Kidney Diseases recommends avoiding dragging the cutting edge along the vessel intima during insertion or removal 2
  • Steeper angles increase risk of perforating the underside of the vessel, as noted by the American Journal of Kidney Diseases 2