Ankle-Brachial Index Measurement and Interpretation

Proper ABI Measurement Procedure

  • The American Heart Association recommends that ABI should be performed by qualified individuals including physicians, nurses, vascular technicians, and other allied health professionals with appropriate training 3
  • Training should include both didactic and experiential learning with knowledge of vascular anatomy, physiology, PAD presentation, and Doppler device function 3
  • Patient should be in supine position for at least 5 minutes before measurement 4
  • The proper sequence for limb pressure measurement is: first arm systolic blood pressure 5, first posterior tibial (PT) artery 2, first dorsalis pedis (DP) artery 2, other PT artery 5, other DP artery 2, and other arm 1, 5
  • If the systolic blood pressure of the first arm exceeds the other arm by >10 mmHg, repeat the first arm measurement and disregard the initial reading 2
  • For research protocols, at least 2 sets of ABI measurements with averaging is recommended for increased accuracy 6

ABI Calculation and Interpretation

  • ABI is calculated by dividing the highest ankle pressure (from either PT or DP artery) by the highest brachial pressure 7
  • Using the lower ABI of both legs will identify more individuals at risk of cardiovascular events, as PAD may be unilateral or more severe in one leg 7, 4
  • ABI <0.90: Confirms diagnosis of peripheral arterial disease (PAD) 2, 8
  • ABI 0.91-1.00: Considered "borderline" in terms of cardiovascular risk; further evaluation is appropriate 8, 9
  • ABI 1.01-1.40: Normal range 8
  • ABI >1.40: Suggests non-compressible vessels; alternative testing needed (toe-brachial index or imaging) 8, 9

Clinical Applications

  • ABI is the first-line noninvasive test for PAD diagnosis when clinical suspicion exists 2, 8
  • Reproducibility is crucial when ABI values are close to threshold values (0.90) 2
  • In clinical practice, an ABI of 0.80 is sufficient to confirm PAD diagnosis considering the 95% CI of differences between measurements is 0.10 2
  • ABI provides incremental information beyond standard risk scores in predicting future cardiovascular events 8, 9
  • Individuals with ABI <0.90 or >1.40 have increased risk of cardiovascular events and mortality, independent of PAD symptoms or other risk factors 8, 9

Common Pitfalls and Caveats

  • Using only one ankle artery or the higher ABI between legs may miss significant disease 7, 4
  • Failure to rest the patient adequately before measurement can affect results 8
  • Training and practice are essential for accurate and reproducible measurements 3, 6