Confirming Correct Tracheal Intubation
Primary Confirmation Methods
- Waveform capnography is the gold standard for confirming tracheal intubation in patients with a perfusing rhythm, with 100% specificity for detecting correct tracheal placement 1
- For awake tracheal intubation, a two-point check is required: visualization of the tracheal lumen and capnography to exclude esophageal intubation 3, 4
- In cardiac arrest patients, capnography may be less reliable due to low pulmonary blood flow; if exhaled CO2 is not detected, confirm tube position with direct laryngoscopy 5, 1
Secondary Confirmation Methods
- Auscultation should be performed bilaterally in the axillae and over the epigastrium - gastric insufflation sounds should not be present if the tube is in the trachea 5
- Check for oxyhemoglobin saturation with a pulse oximeter if there is a perfusing rhythm, but remember that following pre-oxygenation, saturation may not decline for up to 3 minutes even without effective ventilation 5
- An esophageal detector device (EDD) may be considered to confirm endotracheal tube placement in children weighing >20 kg with a perfusing rhythm 5
- In hospital settings, perform a chest x-ray to verify that the tube is not in a bronchus and to identify proper position in the midtrachea 5
Clinical Confirmation of Double-Lumen Tube Placement
- After tracheal intubation with a left-sided double-lumen tube, confirm bilateral air entry with manual ventilation 6
- Inflate the bronchial cuff and check for isolated left-sided air entry when the tracheal lumen is clamped 6
- If clinical confirmation is inconclusive, bronchoscopy is essential to verify correct placement 6
Troubleshooting Deterioration in Intubated Patients
- The American Heart Association recommends considering the DOPE mnemonic if an intubated patient's condition deteriorates:
Important Caveats and Pitfalls
- Capnography may be unreliable in cardiac arrest due to low pulmonary blood flow, giving false negatives despite correct tube placement 5, 1
- Colorimetric CO2 detectors may show a consistent color rather than breath-to-breath change if contaminated with gastric contents or acidic drugs 5
- An IV bolus of epinephrine may transiently reduce pulmonary blood flow and exhaled CO2 below detection limits 5
- Severe airway obstruction and pulmonary edema may impair CO2 elimination below detection limits 5
- A large glottic air leak may reduce exhaled tidal volume through the tube and dilute CO2 concentration 5