Valvular Regurgitation Assessment
Introduction to PISA Method
- The PISA method is used to assess the severity of valvular regurgitation by measuring the radius of the flow convergence zone proximal to the regurgitant orifice, which is then used to calculate Effective Regurgitant Orifice Area (EROA), Regurgitant Volume (RVol), and Regurgitant Fraction (RF), as suggested by the European Society of Cardiology 1
- A PISA radius of 0.5 cm indicates moderate valvular regurgitation, suggesting significant but not severe regurgitant flow that may affect left ventricular function over time if not monitored appropriately, according to the European Society of Cardiology 1
Interpretation of PISA Radius
- For mitral regurgitation, a PISA radius of 0.5-0.9 cm suggests moderate regurgitation, while for aortic regurgitation, similar thresholds apply with slightly different cutoffs depending on the specific guidelines, as suggested by the European Society of Cardiology 1
- A PISA radius of 0.5 cm has implications for left ventricular function, including creating a moderate additional volume load on the left ventricle that may lead to progressive LV dilatation over time, according to the European Society of Cardiology 1
Calculation of EROA
- The formula for calculating Effective Regurgitant Orifice Area (EROA) is EROA = 2πr² × (aliasing velocity ÷ peak MR velocity), which simplifies to EROA = r²/2 with typical settings, as noted by 2
- Using the standard formula with a PISA radius of 0.5 cm, the EROA can be calculated as approximately 0.125 cm², which falls within the moderate range for both mitral and aortic regurgitation, as defined by the American College of Cardiology and the European Society of Cardiology 1, 3
- The following table summarizes the EROA ranges for moderate regurgitation:
| Regurgitation Type | Moderate EROA Range |
|---|---|
| Mitral Regurgitation | 0.2-0.39 cm² |
| Aortic Regurgitation | 0.10-0.29 cm² |
Monitoring and Management
- Follow-up echocardiography is recommended every 6-12 months to monitor for progression of regurgitation and LV dimensions, as suggested by the European Society of Cardiology 1
- LV parameters to monitor include LV end-diastolic and end-systolic dimensions, LV ejection fraction, and LV volumes (indexed to body surface area), according to the European Society of Cardiology 1
Limitations of PISA Method
- The PISA method has limitations, including measurement error, geometric assumptions, and jet direction, which can lead to underestimation of severity, as noted by the American College of Cardiology and the European Society of Cardiology 1, 3
- Multiple regurgitant jets can also lead to underestimation of total regurgitation, according to the American College of Cardiology 3
- A difference of 1mm in PISA radius measurement can change the classification of mitral regurgitation (MR) severity from mild to severe, directly affecting treatment decisions and patient outcomes, as noted by the American College of Cardiology 4, 2
- Non-circular regurgitant orifices, such as crescentic orifices common in secondary MR, can lead to underestimation of EROA, and 3D echocardiography allows direct measurement of EROA without geometric assumptions, typically yielding larger EROA values than 2D PISA in secondary MR 4, 2
- To improve accuracy, use the zoom function to maximize pixels in radius measurement, toggle color on/off to ensure proper valve orifice level identification, and consider angle correction for non-planar flow convergence, and never rely solely on PISA measurements for determining MR severity, but confirm with other parameters, such as mitral inflow patterns, pulmonary vein flow patterns, left atrial volume, and continuous-wave Doppler characteristics of MR jet 4, 2