Chest Tube Management
Introduction to Chest Tube Management
- Chest tube management is crucial for treating pneumothorax, with guidelines from the American Thoracic Society and the British Thoracic Society providing recommendations for proper management 1, 2
Normal Findings and Physiological Processes
- Air movement through previously collapsed airways can produce crackles as the lung re-expands after pneumothorax treatment, according to the American Thoracic Society 1
- Initial output from a chest tube may be minimal or absent if the tube is primarily evacuating air rather than fluid for pneumothorax, as indicated by the British Thoracic Society guidelines 2
Chest Tube Function and Complications
- Never clamp a bubbling chest tube, as this could convert a simple pneumothorax into a tension pneumothorax, as recommended by the British Thoracic Society 2
- Small-caliber chest tubes (10-14F) used for pneumothorax typically have a median drainage time of 2-4 days, and studies using small lumen catheters (2mm) showed successful treatment with a mean drainage time of 48 hours 2
- The absence of output in the first 24 hours does not necessarily indicate tube malfunction, and signs of proper function include bubbling in the water seal chamber, respiratory variation in the water seal chamber, improvement in patient's clinical status, and radiographic improvement on follow-up imaging 2
Evaluation and Management
- A follow-up chest radiograph is essential to confirm proper lung re-expansion, and crackles should gradually diminish as the lung fully re-expands and healing occurs 1
- Concerning signs that require attention include worsening respiratory distress, development of subcutaneous emphysema, persistent pneumothorax on imaging, and patient discomfort around tube site 2
- If a chest tube shows no output in the first night, verify tube position with chest radiograph, assess for respiratory variation in the water seal chamber, evaluate patient clinically for improvement in symptoms, and do not clamp a bubbling chest tube as this could convert a simple pneumothorax into a tension pneumothorax 2
- Consider tube repositioning only if clinical deterioration occurs or follow-up imaging shows inadequate evacuation 2
Troubleshooting and Complications
- The British Thoracic Society guidelines define persistent air leak as continued bubbling through an intercostal tube 48 hours after insertion, and suction should not be applied directly after tube insertion but can be considered after 48 hours if there is persistent air leak or failure of pneumothorax to re-expand 2
- Seek immediate medical attention if patient develops respiratory distress, subcutaneous emphysema develops or worsens, patient becomes hemodynamically unstable, or chest radiograph shows worsening pneumothorax or new effusion 2
- Small-bore tubes (10-14F) are as effective as large tubes (20-24F) for most pneumothoraces, according to the British Thoracic Society guidelines 2