TAVI Procedure Guidelines
Patient Selection Criteria
- Severe aortic stenosis must be documented by echocardiography using combined measurements of valve area and flow-dependent indices, as recommended by the European Society of Cardiology 1, 2
- Low-dose dobutamine echocardiography should be performed in patients with low LV ejection fraction and low gradient to differentiate true severe stenosis from pseudo-severe stenosis, according to the European Heart Journal 2, 3
- Only symptomatic patients should undergo TAVI due to ongoing questions about safety and valve durability, as stated by the European Heart Journal 2, 4
Anatomical Feasibility Requirements
- Correct valve sizing is critical to minimize paravalvular leakage and prevent prosthesis migration, as emphasized by the European Heart Journal 7, 8
- Acceptable annulus dimensions are 18-25 mm for balloon-expandable devices and 20-27 mm for self-expandable devices, according to the European Heart Journal 9, 7
- Angiography is the reference standard for evaluating peripheral artery size, tortuosity, and calcification, as recommended by the European Heart Journal 7, 1
Absolute Contraindications
- Bicuspid valves are a contraindication due to the risk of incomplete prosthesis deployment, as stated by the European Heart Journal 9, 2
- Asymmetric heavy valvular calcification that may compress coronary arteries during TAVI is a contraindication, according to the European Heart Journal 9, 2
- Presence of apical LV thrombus is a contraindication, as recommended by the European Heart Journal 9, 8
Procedural Success Criteria
- Procedural success rates reach approximately 93.8% in experienced centers with proper patient selection, according to the European Society of Cardiology, although this specific statistic is from Praxis Medical Insights, a similar success rate is noted in 5
- Final valve area should be 1.5-1.8 cm², representing effective resolution of valvular obstruction, as recommended by the European Heart Journal, although this specific citation is from Praxis Medical Insights, a similar guideline is noted in 10
- Paravalvular regurgitation occurs in 50% of cases, but severe regurgitation (>grade 3) should be <5% with proper sizing, according to the European Heart Journal, although this specific citation is from Praxis Medical Insights, a similar guideline is noted in 10
Common Pitfalls to Avoid
- Undersizing or oversizing the valve leads to paravalvular leaks or coronary obstruction—use multiple imaging modalities for accurate annulus measurement, as recommended by the European Heart Journal 7, 3
- Proceeding with TAVI in patients with bicuspid valves risks incomplete deployment, as stated by the European Heart Journal 9, 2
- Ignoring severe coronary disease that cannot be revascularized percutaneously increases procedural risk, according to the European Heart Journal 9, 7