Diagnosing Heart Failure
Diagnostic Criteria
- Abnormal global longitudinal strain (GLS) with normal ejection fraction (EF) suggests heart failure with preserved ejection fraction (HFpEF), according to the European Society of Cardiology 1
- A global longitudinal strain (GLS) value worse than -16% should raise concern for myocardial pathology, with values between -16% and -18% considered borderline, and values greater than -18% considered normal, as supported by the American College of Cardiology and the European Association of Cardiovascular Imaging (EACVI) 2
- The following table provides a reference for interpreting GLS values:
| Strain Value | Interpretation |
|---|---|
| > -18% (more negative) | Normal |
| -16% to -18% | Borderline |
| ≤ -16% (less negative) | Abnormal |
Clinical Utility of GLS
- GLS measurements have significant clinical utility in detecting subclinical LV dysfunction in patients with preserved ejection fraction, monitoring cardiotoxicity from chemotherapy, evaluating right ventricular function in pulmonary hypertension, assessing cardiac function in various cardiomyopathies, and serial monitoring of cardiac function over time, with the American College of Cardiology recommending the use of GLS in these clinical scenarios 2
- GLS is a superior and more sensitive marker for detecting subclinical myocardial dysfunction than ejection fraction, allowing early identification of cardiac abnormalities before symptoms or ejection fraction decline occur, as recommended by the American College of Cardiology and the European Society of Cardiology 4, 5, 6
- A 10-15% early reduction in GLS during therapy is the most useful parameter for predicting cardiotoxicity, as stated by the American College of Cardiology 4
- A ≥11% relative reduction in GLS predicts subsequent cardiotoxicity, according to the American College of Cardiology 4
Interpretation of GLS Values
- A GLS value of -14% indicates moderate myocardial dysfunction that requires further clinical evaluation and monitoring, even if the ejection fraction appears preserved 4
- A GLS value of -8.00% represents severe myocardial dysfunction, associated with a higher risk of heart failure hospitalizations, ventricular arrhythmias, cardiovascular death, and all-cause mortality, and may indicate advanced cardiomyopathy or valvular heart disease, according to the European Heart Journal 7, 5, 8
- GLS detects subclinical myocardial damage before ejection fraction decline, with longitudinal function impairment preceding circumferential strain alterations and LVEF reduction, according to the European Heart Journal 9
Limitations and Considerations
- Ensure measurements are performed using the same vendor's equipment for serial assessments due to inter-vendor variability 4, 10, 11
- Image quality significantly affects accuracy of GLS measurements 5
- GLS may be affected by loading conditions and heart rate, as reported by the European Heart Journal and the American College of Cardiology 5
- When interpreting GLS measurements, it is crucial to consider factors such as vendor variability, image quality, and the difference between regional and global measurements 6
Comprehensive Cardiac Evaluation
- Comprehensive cardiac evaluation should include assessment of symptoms, review of cardiovascular risk factors, and evaluation of biomarkers (troponin, BNP/NT-proBNP) 12
- Additional cardiac imaging, such as stress echocardiography or cardiac MRI, may be necessary to assess for ischemia and monitor for progression 12
- Investigation of potential causes, including coronary artery disease assessment, evaluation for cardiomyopathies, and review of medication history, is crucial for guiding management 12
- The American College of Radiology recommends that a severely abnormal GLS value warrants comprehensive cardiac evaluation, including assessment of symptoms, other cardiac imaging, and biomarkers, as well as identification of underlying etiology through additional testing, and close monitoring with more frequent follow-up echocardiography 7