Diagnostic Approach for Cryptococcal Meningitis
Diagnostic Tests
- India ink microscopy has a sensitivity of 97-100% when performed with cytospin centrifugation to increase yield, and is a rapid and inexpensive test, although it requires experienced laboratory personnel for accurate interpretation 1, 2
- A negative multiplex PCR does not rule out cryptococcal meningitis, especially in patients with prior antifungal exposure or low fungal burden, according to the Infectious Diseases Society of America 3
Diagnostic Algorithm
- Consider India ink staining if rapid microscopy expertise is available, as it can provide rapid results with high sensitivity 1
- If multiplex PCR is performed and negative, do not exclude cryptococcal meningitis—proceed with CrAg testing and culture, as recommended by the Centers for Disease Control and Prevention 3