Laboratory Tests for Diagnosing Type 2 Diabetes
Primary Diagnostic Tests
- The American Diabetes Association recommends diagnosing type 2 diabetes using any one of four laboratory tests: fasting plasma glucose (FPG) ≥126 mg/dL, 2-hour plasma glucose ≥200 mg/dL during a 75-g oral glucose tolerance test (OGTT), hemoglobin A1C ≥6.5%, or random plasma glucose ≥200 mg/dL in symptomatic patients 1, 2, 3
- Fasting Plasma Glucose (FPG) has a diagnostic threshold of ≥126 mg/dL (7.0 mmol/L) and requires no caloric intake for at least 8 hours 1, 2, 3
- The American Diabetes Association states that FPG is the preferred screening test because it is faster, easier to perform, more convenient, acceptable to patients, and less expensive than OGTT 4
- Hemoglobin A1C has a diagnostic threshold of ≥6.5% (48 mmol/mol) and must be performed using a method certified by the National Glycohemoglobin Standardization Program (NGSP) and standardized to the Diabetes Control and Complications Trial (DCCT) assay 1, 2, 3, 6
- 2-Hour Plasma Glucose During OGTT has a diagnostic threshold of ≥200 mg/dL (11.1 mmol/L) and requires a 75-g anhydrous glucose load dissolved in water 1, 2, 3, 7
- Random Plasma Glucose has a diagnostic threshold of ≥200 mg/dL (11.1 mmol/L) and is only valid in patients with classic symptoms: polyuria, polydipsia, unexplained weight loss, or hyperglycemic crisis 1, 2, 3
Confirmation Requirements
- The American Diabetes Association recommends confirming the diagnosis with a second abnormal test result, unless the patient has unequivocal hyperglycemia (symptomatic with random glucose ≥200 mg/dL) 1, 8, 2, 3, 6
- Confirmation options include repeating the same test on a different day or performing a different diagnostic test (e.g., if A1C is 7.0%, confirm with FPG ≥126 mg/dL) 8, 6
When NOT to Use A1C
- The American Diabetes Association recommends using only plasma glucose criteria (FPG or OGTT) in specific situations, including sickle cell disease, pregnancy, glucose-6-phosphate dehydrogenase deficiency, HIV, hemodialysis, recent blood loss or transfusion, erythropoietin therapy, iron-deficiency anemia, and hemoglobin variants (hemoglobinopathies) 1, 8, 2, 6
Critical Pitfalls to Avoid
- Marked discordance between A1C and plasma glucose should raise suspicion of A1C assay interference, and for patients with hemoglobin variants, use an A1C assay without interference or switch to glucose-based criteria 1, 8, 2, 6
- Using wrong collection tubes or delayed processing causes falsely low glucose values due to glycolysis, and blood must be in tubes with glycolytic inhibitors and processed promptly 5