Evidence‑Based Recommendations for Entropy Monitoring in General Anaesthesia

Definition and Indices

  • Entropy monitoring processes the electroencephalogram (EEG) to generate two numerical indices—State Entropy (SE) and Response Entropy (RE)—that reflect the brain’s electrical activity in response to anaesthetic drugs, providing a quantitative measure of hypnotic depth. 1

Target Entropy Values for Different Depths of Anaesthesia

Depth of Anaesthesia State Entropy (SE) Response Entropy (RE)
Awake (baseline) 80–100 (approx.) 80–100 (approx.)
Light sedation 60–80 60–85
General anaesthesia 40–60 40–65
Deep hypnosis < 40 < 40
  • The ranges above are derived from validated research correlating entropy indices with anaesthetic depth, supporting their use for intra‑operative monitoring. 1

Clinical Benefits of Using Entropy Monitoring

  • The Association of Anaesthetists recommends that processed EEG (entropy) monitoring can reduce the risk of accidental awareness during general anaesthesia. 1
  • Use of entropy monitoring is associated with shorter emergence and earlier recovery times after surgery. 1
  • Incorporating entropy monitoring may lower the incidence of postoperative delirium and postoperative cognitive dysfunction in the postoperative period. 1

Interpretation and Integration with Other Parameters

  • Entropy values should be interpreted in conjunction with additional clinical parameters, such as end‑tidal anaesthetic concentration, haemodynamic responses, and patient movement, to ensure accurate assessment of anaesthetic depth. 1

Implementation Recommendations

  • When total intravenous anaesthesia (TIVA) is employed—especially with neuromuscular blockade—processed EEG (entropy) monitoring is advised to optimise drug dosing and avoid awareness. 1
  • For inhalational anaesthesia, maintain end‑tidal anaesthetic concentration greater than 0.7 age‑adjusted MAC and enable an audible alarm; this practice, combined with entropy monitoring, helps further reduce the risk of intra‑operative awareness. 1

Anesthetic Management for Intraoperative Neuromonitoring

Introduction to Anesthetic Techniques

  • The American Society of Anesthesiologists recommends using total intravenous anesthesia (TIVA) with propofol and short-acting opioids (fentanyl, remifentanil) for intraoperative neuromonitoring, as it allows for rapid recovery with minimal residual effects 2

Anesthetic Effects on Evoked Potentials

  • The amplitude of evoked responses is proportional to the number of stimulated motor neurons, making them highly sensitive to neuromuscular blocking agents and anesthetics 3
  • The use of sevoflurane and isoflurane can potentiate partial neuromuscular blockade, reducing the train-of-four ratio 3

Clinical Implications for Anesthetic Management

  • The American College of Cardiology recommends avoiding nitrous oxide due to its effects on intestinal function and increased risk of postoperative nausea and vomiting 2
  • Nitrous oxide can expand gas bubbles, resulting in potential adverse neurological effects through expansion of gas emboli 4

Considerations for Neuromonitoring

  • The International Society for the Advancement of Spine Surgery recommends using transcranial motor-evoked potentials (TcMEPs) in addition to somatosensory-evoked potentials (SSEPs) for intraoperative monitoring, as TcMEPs are more sensitive for detecting spinal cord ischemia 3
  • The Society for Neuroscience in Anesthesiology and Critical Care recommends that anesthesiologists should not rely solely on index values displayed by processed EEG monitors, but rather develop a basic understanding of EEG waveforms and spectral power analysis 5, 6, 7

Decision-Making Algorithm for Anesthetic Technique

  • When planning intraoperative neuromonitoring, the first-line technique should be TIVA with propofol and short-acting opioids, with quantitative neuromuscular monitoring when using neuromuscular blockers 5, 6