Low-Dose Computed Tomography Protocol for Lung Cancer Screening

Technical Parameters for Lung Screening

  • The European Respiratory Society recommends using a multi-slice helical CT scanner with 120 kVp tube voltage and 20-40 mA tube current for lung cancer screening, with a slice thickness of 1.25 mm and rotation time of 0.5 seconds 1, 2
  • The American College of Radiology suggests that the tube current should be adjusted based on the manufacturer, with 40 mA for GE scanners and 20 mA for Siemens scanners, to maintain a consistent radiation dose 1, 2
  • The European Respiratory Society recommends acquiring contiguous slices from the thoracic inlet to the adrenal glands in a single breath-hold without contrast material, with a target effective dose of ≤3 mGy 1, 2, 3
  • The American Journal of Respiratory and Critical Care Medicine suggests that the radiation dose should be tracked using the CT dose index and dose-length product, with a target effective dose of ≤3 mGy for screening examinations 4

Reconstruction and Display Parameters

  • The Journal of the National Comprehensive Cancer Network recommends using a slice thickness of ≤1.0 mm for optimal nodule detection and measurement, with a preferred slice width of ≤1.0 mm and an acceptable slice width of ≤2.5 mm 5
  • The European Respiratory Journal suggests using a lung window with a width of 1500 and a level of -650, and a mediastinal window with a width of 350 and a level of 25, for nodule assessment 1, 2, 3

Radiation Dose Considerations

  • The American family physician reports that the median radiation dose with low-dose protocols is approximately 22% of standard-dose CT without compromising diagnostic accuracy, with a target effective dose of ≤3 mGy for screening examinations 6
  • The American Journal of Respiratory and Critical Care Medicine recommends using the CT dose index and dose-length product to track radiation dose, with a target effective dose of ≤3 mGy for screening examinations 4

Quality Assurance Requirements

  • The American College of Radiology requires that scanners meet or exceed quality standards, with annual protocol review and technologist training in the specific low-dose protocol 4
  • The Journal of the National Comprehensive Cancer Network recommends using training sets of screening LDCTs to ensure consistent application of reporting systems across radiologists, with pre-dismissal review of CT data sets to ensure complete imaging and adequate visualization 4, 5