Pre‑Dialysis Patient Assessment
Vascular Access Evaluation
- Evaluate arteriovenous fistula or graft integrity with hydraulic compression testing and verify needle placement and graft flow configuration to ensure adequate blood flow and minimize recirculation. 1
Volume‑Status Assessment
- Assess patients for signs of volume overload (peripheral edema, jugular venous distension, pulmonary congestion) or dehydration, recognizing that achieving euvolemia is essential for successful dialysis and complication avoidance. 2
Laboratory Baseline Assessment
- Obtain a predialysis BUN sample immediately before the first dialysis session using a technique that avoids dilution by saline or heparin (draw from the arterial needle before tubing is connected, or flush venous catheters of heparin/saline and then collect the sample). This provides an accurate baseline for adequacy monitoring. 3
Infection Screening
- Screen all incident hemodialysis patients for hepatitis B and C before entry into the dialysis unit; for hepatitis C, perform anti‑HCV antibody testing with confirmatory nucleic acid testing (NAT) if positive, and consider initial NAT in high‑prevalence settings because HCV‑RNA can be detectable in ~10 % of anti‑HCV‑negative patients during the window period. Draw NAT samples before dialysis and obtain baseline ALT for monthly monitoring (ALT has ~83 % sensitivity and ~90 % specificity for acute HCV infection). 4
Cardiac Evaluation
- Perform a baseline 12‑lead ECG and transthoracic echocardiogram within 1–3 months after the patient reaches dry weight to detect left‑ventricular hypertrophy, systolic or diastolic dysfunction; note that ≥75 % of patients have such cardiac abnormalities at dialysis initiation. If left‑ventricular ejection fraction is <40 %, evaluate for coronary artery disease. 2
Clinical Status Review
- Review vital signs and assess for uremic manifestations (e.g., nausea, vomiting, altered mental status, pericarditis, bleeding tendency) and for protein‑energy wasting, as these clinical factors guide the decision to start dialysis independent of a specific eGFR threshold. 5
Treatment Parameter Documentation
- Record prescribed dialysis parameters (dialyzer type, blood‑flow rate, dialysate flow rate, session duration) and verify them against actual machine settings; check the dialysis machine maintenance log for the latest calibration results and document extracorporeal pressures to establish a baseline for subsequent adequacy monitoring. 1
Common Pitfalls
- Do not draw predialysis BUN samples after dialysis has begun or when saline/heparin is present in the circuit, as this dilutes the sample and yields falsely low Kt/V values.
- Avoid basing dialysis initiation solely on eGFR; prioritize uremic symptoms, protein‑energy wasting, and inability to manage metabolic abnormalities, especially in patients with heart failure, hypoalbuminemia, high BUN/creatinine ratio, or hyperuricemia, who often require earlier treatment. [3] [5]
Comprehensive Assessment of Hemodialysis Patients
Pre-Dialysis Assessment
- The American Journal of Kidney Diseases recommends reviewing patient's clinical status including vital signs, with special attention to blood pressure measurements, which should not rely solely on pre-dialysis readings as they are imprecise estimates of interdialytic blood pressure 6
- Assess for signs of volume overload or dehydration, as recommended by the American Journal of Kidney Diseases 7
- Evaluate access site for patency and signs of infection or complications, as suggested by the American Journal of Kidney Diseases 8
- Review A/V needle placement, proximity, and orientation with patient care staff and patient, as recommended by the American Journal of Kidney Diseases 8
- Obtain predialysis BUN sample immediately prior to dialysis, using a technique that avoids dilution with saline or heparin, as recommended by the American Journal of Kidney Diseases 9
Intra-Dialysis Monitoring
- Monitor blood pressure throughout the session to assess for intradialytic hypotension, as recommended by the American Journal of Kidney Diseases 8
- Document extracorporeal pressures compared to previous sessions with prescribed Qb, as suggested by the American Journal of Kidney Diseases 8
- Check if prepump arterial pressures exceed 200 mmHg or if pressures are close to upper limits per dialysis unit policy, as recommended by the American Journal of Kidney Diseases 8
- Track effective hemodialysis treatment time (Td) to ensure delivery of prescribed treatment duration, as suggested by the American Journal of Kidney Diseases 8
Post-Dialysis Assessment
- Assess patient for symptoms of dialysis disequilibrium syndrome, as recommended by the American Journal of Kidney Diseases 10
- Evaluate for signs of excessive ultrafiltration, as suggested by the American Journal of Kidney Diseases 11
- Document patient's post-dialysis weight and compare to target dry weight, as recommended by the American Journal of Kidney Diseases 11
- Obtain postdialysis BUN sample using the slow flow/stop pump technique to prevent sample dilution with recirculated blood, as suggested by the American Journal of Kidney Diseases 9
Dialysis Adequacy Evaluation
- Calculate Kt/V or URR using properly collected pre and post-dialysis BUN samples, as recommended by the American Journal of Kidney Diseases 9
- Measure delivered dose of dialysis at least monthly to ensure adequate treatment, as suggested by the American Journal of Kidney Diseases 10
- If Kt/V or URR is below target, investigate potential causes, including clearance (K) less than assumed, effective hemodialysis treatment time (Td) less than prescribed, or errors in blood sampling or processing for BUN concentration, as recommended by the American Journal of Kidney Diseases 12