Cardiac Resynchronization Therapy for Heart Failure

Device Components and Mechanisms

  • The American College of Cardiology recommends CRT-D devices, which consist of three pacing leads and defibrillation capability, to restore synchronized contraction between ventricles and correct interventricular and intraventricular conduction delays 1
  • The European Heart Journal states that standard ICDs without resynchronization capability treat ventricular arrhythmias but do not address mechanical dyssynchrony 2, 3

Physiologic Benefits and Clinical Outcomes

  • The European Journal of Heart Failure reports that CRT-D increases left ventricular ejection fraction by 5-10% absolute points and reduces LV end-systolic volume by 18-26% through reverse remodeling 6, 1
  • The American College of Cardiology recommends CRT-D to reduce all-cause mortality by 36% in NYHA class III-IV patients compared to medical therapy alone 1
  • The European Heart Journal states that ICDs alone reduce mortality by 23-31% in primary prevention populations with reduced ejection fraction 3

Specific Indications by Patient Population

  • The European Heart Journal recommends CRT-P or CRT-D for NYHA class III or ambulatory class IV patients with LVEF ≤35%, QRS ≥120 ms in sinus rhythm on guideline-directed medical therapy, to reduce morbidity and mortality 4, 7, 6
  • The American College of Cardiology recommends CRT for NYHA class II, III, or ambulatory IV patients with LVEF ≤35%, sinus rhythm, LBBB pattern with QRS ≥150 ms on optimal medical therapy 2

Critical Contraindications and Caveats

  • The American College of Cardiology states that QRS duration <120 ms, even with echocardiographic evidence of dyssynchrony, is an absolute contraindication for CRT 2, 1
  • The European Heart Journal reports that NYHA class IV with refractory symptoms requiring continuous intravenous inotropes is an absolute contraindication for CRT 1

Device Selection Algorithm

  • The European Heart Journal recommends CRT-D over CRT-P for patients with a secondary prevention indication for ICD (prior cardiac arrest or sustained ventricular arrhythmia) 4, 5
  • The American College of Cardiology states that standard ICD is appropriate for primary or secondary prevention of sudden cardiac death in patients with LVEF ≤35% who do not meet CRT criteria 2, 3

Special Populations

  • The European Journal of Heart Failure reports that CRT reduces heart failure events by 34-41% in NYHA class II patients with LVEF ≤30%, ischemic or nonischemic cardiomyopathy, LBBB with QRS ≥130-150 ms 7, 6
  • The American Heart Association recommends guideline-directed device therapy in diabetic patients meeting standard indications 10