Assessing PET MPI for Microvascular Disease
Key Parameters to Evaluate
- The American College of Cardiology recommends calculating the myocardial blood flow reserve (MBFR or MFR) to assess microvascular disease, with values <1.9-2.0 indicating microvascular dysfunction, even in the absence of visible perfusion defects 1, 2, 3
- The American Heart Association suggests that absolute myocardial blood flow (MBF) values should be quantified for both rest and stress (hyperemic) conditions 4
- The myocardial flow reserve (MFR) should be calculated as the ratio of stress to rest absolute myocardial blood flow, with normal MFR being ≥2.0, and values <2.0 suggesting impaired coronary flow reserve 2, 4
- A uniform reduction in MFR across multiple coronary territories is characteristic of microvascular disease, rather than focal epicardial stenosis 3, 4
- The left ventricular ejection fraction (LVEF) reserve should be evaluated, as abnormal LVEF reserve provides incremental value in predicting microvascular dysfunction 5, 6
Advantages of PET for Microvascular Assessment
- PET offers superior spatial resolution compared to SPECT, improving diagnostic accuracy, particularly in women and obese patients 2, 3
- PET allows for the calculation of absolute blood flow across coronary vessels, essential for detecting microvascular dysfunction 2, 3
- The diagnostic accuracy of PET is approximately 20% higher than SPECT MPI (88% versus 67%, p=0.009) 3
Interpretation Guidelines
- A normal MFR (≥2.0) indicates normal coronary vasodilatory capacity 4
- A mildly reduced MFR (1.8-2.0) suggests early microvascular dysfunction, requiring optimization of medical therapy 4
- A moderately to severely reduced MFR (<1.8) indicates significant microvascular dysfunction 4
Clinical Correlation
- MFR findings should be correlated with patient symptoms, particularly in women, who have a higher prevalence of non-obstructive CAD and microvascular dysfunction 2, 3
- The presence of risk factors for microvascular disease, such as diabetes, hypertension, and smoking, should be considered when interpreting borderline MFR values 4
Technical Considerations
- Rb-82 and N-13 ammonia are the most commonly used radioisotopes for PET MPI 5
- Hybrid PET/CT can be used to evaluate both functional and anatomical aspects of coronary circulation 2, 7
Pitfalls to Avoid
- Sole reliance on visual assessment of perfusion defects should be avoided, as microvascular disease may not produce visible perfusion abnormalities 2, 4
- Globally reduced MFR should not be misinterpreted as technical error, as it may represent diffuse microvascular disease or balanced multi-vessel epicardial disease 2, 4
- Reduced MFR has prognostic value, independently predicting adverse cardiovascular events, even in patients with normal perfusion images 4