Mesna Administration for Tracheostomy Suctioning
Guideline Recommendations
- The American Thoracic Society recommends avoiding administration of medications not approved for aerosol use through tracheostomy unless appropriate studies are performed 1, 3
- The American Thoracic Society advises that drugs safely nebulized in mouth-breathing patients may achieve toxic concentrations when administered via tracheostomy due to complete respiratory tract absorption without first-pass metabolism 1, 3
- The American Academy of Otolaryngology-Head and Neck Surgery recommends against instillation of saline before suctioning due to increased risk of coughing and aerosolization with little evidence of benefit 4, 5, 6
Proper Suctioning Technique
- The American Academy of Otolaryngology-Head and Neck Surgery recommends using closed-circuit suctioning systems with inline suction catheters for both mechanically ventilated and non-ventilated patients to decrease aerosolization 4, 5, 6
- The American Academy of Otolaryngology-Head and Neck Surgery suggests passing a soft suction catheter beyond the tracheostomy tube tip to establish airway patency and perform therapeutic suction 7
- The American Academy of Otolaryngology-Head and Neck Surgery recommends applying appropriate negative pressure (100-200 cmH₂O) during suctioning 4, 5
Managing Thick Secretions
- The American Academy of Otolaryngology-Head and Neck Surgery recommends performing frequent suctioning to prevent mucus buildup and airway obstruction 4, 5
- The American Academy of Otolaryngology-Head and Neck Surgery suggests using vibrating mesh nebulizers that maintain closed-circuit systems for mechanically ventilated patients with thick secretions requiring inhaled medications 4, 6
- The American Academy of Otolaryngology-Head and Neck Surgery recommends using a spacer for metered-dose inhaled medications via tracheostomy for non-ventilated patients 4, 6
Safety Considerations
- The American Academy of Otolaryngology-Head and Neck Surgery advises avoiding jet nebulizers as they can aerosolize particles up to 80 cm 4, 6
- The American Academy of Otolaryngology-Head and Neck Surgery recommends using appropriate PPE during all suctioning procedures 4, 5
- The American Academy of Otolaryngology-Head and Neck Surgery suggests placing patients in negative pressure rooms or rooms with HEPA filters if thick secretions cause recurrent inline circuit occlusion 4, 5
Common Pitfalls
- The American Journal of Respiratory and Critical Care Medicine recommends not instilling any medications into the tracheostomy for suctioning purposes unless they are FDA-approved for this specific indication 1, 3
- Anaesthesia recommends avoiding using stiff introducers or bougies during suctioning as they may create false passages 7
- Anaesthesia advises not attempting vigorous hand ventilation through a potentially displaced tracheostomy tube, as this can cause surgical emphysema 7