Factor VIII Measurement and Clinical Applications
Understanding Factor VIII Measurement
- The American Society of Hematology recommends classifying the severity of hemophilia A based on plasma levels of factor VIII activity: severe if <1%, moderate if between 1% and 5%, and mild if >5% and <40% of normal 2, 3
- Factor VIII activity is the standard measurement used to classify the severity of hemophilia A, with levels reported as a percentage of normal or in international units per deciliter (IU/dL) 1, 2
Laboratory Testing Methods
- The International Society on Thrombosis and Haemostasis recommends using one of two main assay types to measure factor VIII activity: one-stage clotting assay (OSCA) or chromogenic assay (CHR) 4, 5
Clinical Applications
- Factor VIII activity/level measurements are essential for diagnosing and classifying hemophilia A, monitoring response to factor replacement therapy, detecting inhibitors, and guiding dosing decisions for factor concentrates 2, 6
- The World Federation of Hemophilia suggests that factor VIII activity measurements should be performed along with mixing studies and Bethesda assays to quantify the inhibitor titer in patients with suspected inhibitors 7, 8
Important Considerations
- When measuring factor VIII levels after administration of modified clotting factor concentrates, the choice of assay method is critical as some products may give misleading results with certain reagents 4, 5