Praxis Medical Insights

Est. 2024 • Clinical Guidelines Distilled

Made possible by volunteer editors from the University of Calgary & University of Alberta

Last Updated: 10/29/2025

Intrauterine Devices for Contraception

Device Characteristics

  • Mirena contains 52 mg of levonorgestrel, while Kyleena contains 19.5 mg of levonorgestrel, with Mirena having a higher daily hormonal release rate due to its higher total hormone content 1, 2
  • The American College of Obstetrics and Gynecology recommends considering the differences in hormonal content and device size when selecting an intrauterine device for contraception 1, 2

Approved Duration of Use

  • Mirena is approved by the FDA for 5 years of use, although studies demonstrate efficacy for up to 7-8 years, with the American College of Obstetrics and Gynecology acknowledging its extended use 1, 2
  • Both devices maintain failure rates of less than 1% during their approved use period, according to the American College of Obstetrics and Gynecology 2

Contraceptive Efficacy

  • Both devices are highly effective with typical and perfect use failure rates of less than 1%, as reported by the American College of Obstetrics and Gynecology 2
  • The American College of Obstetrics and Gynecology considers both devices to be equally effective for preventing pregnancies, despite the lack of direct comparative studies 1, 2

Therapeutic Indications

  • Mirena has approved indications beyond contraception, including the treatment of menorrhagia (heavy menstrual bleeding), as recommended by the American College of Radiology 2
  • The American College of Radiology considers Mirena to be a first-line treatment for heavy menstrual bleeding 2

Effects on Menstrual Bleeding

  • Both devices reduce menstrual bleeding, but Mirena produces a more marked reduction due to its higher hormonal content, as reported by the American College of Obstetrics and Gynecology 2
  • Many Mirena users experience amenorrhea (absence of menstruation) or infrequent bleeding, according to the American College of Obstetrics and Gynecology 2

Safety Profile

  • Both devices share the same general safety profile, being highly safe reversible contraceptive methods, as stated by the American College of Obstetrics and Gynecology 1, 2
  • The Centers for Disease Control and Prevention (CDC) note that the risk of pelvic infection is small and limited to the first 20-21 days after insertion 2
  • The American College of Obstetrics and Gynecology lists contraindications for both devices, including current or recent (within the last 3 months) pelvic inflammatory disease 1, 2