Extended Antigen Matching and Identification Protocols in Pre‑Transfusion Testing
Extended Antigen Matching for Specific Populations
- Patients with sickle‑cell disease should receive red‑cell units matched for an extended antigen panel (C/c, E/e, K, Jka/Jkb, Fya/Fyb, S/s) regardless of the auto‑control result. 1
Standard Pre‑Transfusion Testing Procedures
- Routine pre‑transfusion work‑up must include ABO and RhD typing together with an antibody screen before any cross‑match is performed. 2
Patient Identification Requirements
- Two independent patient identifiers must be verified before blood‑sample collection to ensure correct patient identification. 2