Measurement and Interpretation of DLCO
Technical Considerations
- The European Respiratory Society recommends hemoglobin correction in patients with autoimmune diseases, as anemia reduces hemoglobin available for CO binding and falsely lowers DLCO 1, 2
- Carboxyhemoglobin adjustment is important for accurate results, particularly in patients being monitored for drug toxicity, according to the European Respiratory Society 1, 2
- Strict adherence to lung function standards and guidelines, as recommended by the European Respiratory Society, reduces test variability and requires meticulous quality control to ensure reliable results 4
Quality Control and Patient Considerations
- The European Respiratory Society emphasizes the importance of proper quality control measures, including meticulous quality control, to ensure reliable results, especially when tracking disease progression over time 4