Follow-up Protocol for Dilated Ascending Aorta
Initial Assessment
- The European Society of Cardiology recommends transthoracic echocardiography (TTE) at diagnosis to assess aortic valve anatomy, function, aortic root, and ascending aorta diameters in patients with dilated ascending aorta 1, 4
- Cardiovascular computed tomography (CCT) or cardiovascular magnetic resonance (CMR) is recommended to confirm TTE measurements, rule out aortic asymmetry, and determine baseline diameters for follow-up in patients with dilated ascending aorta 1, 3
- CMR or CCT is required for surveillance of aneurysms at the distal ascending aorta, aortic arch, or descending thoracic aorta, as TTE is not recommended for these locations 4
Follow-up Intervals Based on Aortic Diameter (Non-Heritable Disease)
- For aortic diameters of 40-44 mm, the European Society of Cardiology recommends baseline CCT/CMR and reimaging in one year 1, 3
- For aortic diameters of 45-49 mm, the European Society of Cardiology recommends confirmation by CCT or CMR, then annual imaging 1, 3
- For aortic diameters of 50-54 mm, the European Society of Cardiology recommends imaging every 6 months until threshold for intervention is reached 1, 4
- For aortic diameters ≥55 mm, the European Society of Cardiology recommends consideration of surgical intervention 5, 3
Special Considerations Affecting Follow-up Frequency
- The European Society of Cardiology recommends more frequent monitoring (every 6 months) and consideration of earlier intervention for patients with a growth rate ≥3 mm/year 1, 3
- The European Society of Cardiology recommends lower thresholds for intervention and more frequent monitoring for patients with resistant hypertension, short stature, root phenotype, age <50 years, or desire for pregnancy 5, 3
Imaging Modality Selection
- The European Society of Cardiology recommends TTE for follow-up of aortic root and proximal ascending aorta if there is agreement between TTE and CCT/CMR measurements 1, 4
- The European Society of Cardiology recommends CMR or CCT for surveillance if there is a difference of ≥3 mm between TTE and CCT/CMR measurements 1
- The European Society of Cardiology recommends CMR over CCT for long-term follow-up in young patients to minimize radiation exposure 2, 3
Post-Intervention Follow-up
- The European Society of Cardiology recommends imaging within 1 month, then yearly for first 2 years, then every 5 years if stable after open repair for thoracic aortic aneurysm 2
- The European Society of Cardiology recommends follow-up imaging at 1 and 12 months post-operatively, then yearly until the fifth post-operative year if no abnormalities are documented after endovascular repair (TEVAR) 5
Pitfalls and Caveats
- The European Society of Cardiology recommends using the same imaging technique and center for follow-up to avoid measurement inconsistencies 1
- The European Society of Cardiology highlights the importance of patient compliance with follow-up programs, as non-compliance is associated with higher rupture rates 2
- The European Society of Cardiology recommends special attention for patients with bicuspid aortic valve due to associated aortopathy and potentially higher risk of complications 3