Infection Control in the ICU
Critical Items Requiring Sterilization
- The Centers for Disease Control and Prevention recommends that critical items, such as surgical instruments, needles, and catheters, that penetrate sterile tissue or the vascular system must be sterile 1, 2
- The American College of Cardiology and other medical societies agree that implants of any kind also require sterilization 1, 2
Semicritical Items Requiring Sterilization or High-Level Disinfection
- The Centers for Disease Control and Prevention guidelines state that semicritical items, such as endotracheal tubes, tracheostomy tubes, and anesthesia breathing circuit components, require high-level disinfection or sterilization 3, 4, 2
- The American Thoracic Society recommends that bronchoscopes, whether flexible or rigid fiberoptic, must be sterilized or high-level disinfected 1, 2
- The Society for Healthcare Epidemiology of America advises that respirometers, ventilator thermometers, and small-volume medication nebulizers require sterilization or high-level disinfection between patients 3, 5, 6
Equipment That Does NOT Require Routine Sterilization
- The Centers for Disease Control and Prevention recommends that internal machinery of anesthesia equipment, pulmonary-function testing machines, and ventilators do not require routine sterilization 3, 4, 5, 6
- However, the American Association for Respiratory Care suggests changing mouthpieces and filters of spirometers and peak flow meters between patients 3, 4, 5, 6
Special Considerations for ICU Equipment
- The Centers for Disease Control and Prevention warns against using large-volume room-air humidifiers that create aerosols unless they can be sterilized or subjected to high-level disinfection at least daily 3, 4, 5, 6
- The American Thoracic Society recommends using only sterile fluid for nebulization and dispensing it aseptically 3, 5, 6
- The Society for Healthcare Epidemiology of America advises using single-dose vials whenever possible for aerosolized medications 3, 5, 6
Critical Processing Principles
- The Centers for Disease Control and Prevention emphasizes that cleaning must always precede high-level disinfection and sterilization 1, 2
- The Spaulding classification system guides processing decisions, with critical items requiring sterilization, semicritical items requiring high-level disinfection or sterilization, and noncritical items requiring low-level disinfection 1, 2
Common Pitfalls to Avoid
- The Centers for Disease Control and Prevention warns against skipping the cleaning step, as organic material prevents effective sterilization/disinfection 1, 2
- The American College of Cardiology and other medical societies advise against basing processing decisions on patient diagnosis, instead using the same standards regardless of whether the patient has a known infection 1, 2
- The Society for Healthcare Epidemiology of America recommends following manufacturer's instructions for reprocessing times, temperatures, and chemical concentrations 3, 4, 5