Tracheostomy Tube Care and Maintenance
Essential Tracheostomy Care Components
- The American Journal of Respiratory and Critical Care Medicine recommends always maintaining an emergency kit containing: manual resuscitation bag, suction source, suction catheters, replacement tracheostomy tubes (current size and one size smaller), extra ties, shoulder roll, scissors, and emergency contact information 3
- The American Journal of Respiratory and Critical Care Medicine suggests ensuring caregivers are trained in CPR specific to tracheostomy patients, including bag-to-tracheostomy ventilation 4
- For patients with patent upper airways, the American Journal of Respiratory and Critical Care Medicine recommends training should include mouth-to-mouth ventilation with stoma occlusion 4
- The American Journal of Respiratory and Critical Care Medicine recommends using the "premeasured technique" for routine suctioning, inserting the catheter to a predetermined depth with the distal side holes just exiting the tip of the tracheostomy tube 5
- The American Journal of Respiratory and Critical Care Medicine suggests twirling or rotating the catheter between fingers during insertion to reduce friction and effectively clear secretions from all areas of the tube wall 5
- The American Journal of Respiratory and Critical Care Medicine recommends using premarked catheters to ensure proper insertion depth and avoid epithelial damage 5
- The American Journal of Respiratory and Critical Care Medicine suggests clean technique is appropriate for home care with thorough handwashing before and after each suctioning procedure 6
- After suctioning, the American Journal of Respiratory and Critical Care Medicine recommends flushing the catheter with tap water until secretions are cleared, wiping the outside with alcohol, and allowing to air dry 5
- For mechanically-ventilated patients, the American Academy of Otolaryngology-Head and Neck Surgery recommends using closed-circuit suctioning systems with inline suction catheters to decrease aerosolization risk 7
- The American Journal of Respiratory and Critical Care Medicine recommends securing the tube with ties tight enough to prevent dislodgement but loose enough to allow one finger to slip beneath the tie 6
- The American Academy of Otolaryngology-Head and Neck Surgery suggests foam straps place minimal stress on the skin compared to twill ties and decrease risk of skin breakdown 7
- The American Journal of Respiratory and Critical Care Medicine recommends keeping the peristomal skin clean and dry to prevent infection and pressure necrosis 3
- The American Journal of Respiratory and Critical Care Medicine suggests cleaning the stoma daily with soap and water; 1.5% hydrogen peroxide can be used to remove encrusted secretions, followed by thorough rinsing and drying 3
- The American Journal of Respiratory and Critical Care Medicine recommends avoiding routine use of ointments and creams; petroleum-based products are contraindicated 3
- If dressings are used, the American Journal of Respiratory and Critical Care Medicine suggests they should promote moisture movement away from the skin and be loose and nonocclusive 3
- The American Journal of Respiratory and Critical Care Medicine recommends following a systematic approach for tube changes, including checking tube integrity and flexibility before insertion, suctioning the current tube, positioning the patient with neck in slight extension using a shoulder roll, removing the old tube in an upward and outward arc, inserting the new tube in a downward, inward arc, immediately removing the obturator after insertion, securing the ties and checking placement 3
- Ideally, the American Journal of Respiratory and Critical Care Medicine recommends having two trained adults present for tube changes 3
- For patients with cuffed tubes, Praxis Medical Insights recommends maintaining cuff pressure between 20-30 cmH2O to prevent tracheal injury while maintaining circuit integrity 8
- Praxis Medical Insights suggests ensuring adequate humidification to prevent secretion thickening and airway dryness 8
- Praxis Medical Insights recommends using heat moisture exchangers (HMEs) over large-volume humidifiers 8
Special Considerations
Infection Prevention
- Praxis Medical Insights recommends decontaminating hands before and after contact with the tracheostomy tube or any respiratory device 8
- Praxis Medical Insights suggests wearing gloves when handling respiratory secretions or contaminated objects 8
- Anaesthesia recommends changing the fixation daily or more often if there is oozing (hemorrhage or pus) 2
Patient Transport
- The American Academy of Otolaryngology-Head and Neck Surgery recommends equipping non-ventilated patients with a heat moisture exchanger with viral filter during transport 7
- For ventilated patients, the American Academy of Otolaryngology-Head and Neck Surgery suggests ensuring the cuff is optimally inflated with a closed-circuit to decrease aerosolization 7
- The American Academy of Otolaryngology-Head and Neck Surgery recommends wearing surgical masks over both the patient's face and the tracheostomy tube during transport 7
Environmental Safety
- The American Journal of Respiratory and Critical Care Medicine recommends avoiding exposure to dust, smoke, lint, pet hair, powder, sprays, and small objects 3
- The American Journal of Respiratory and Critical Care Medicine suggests restricting contact with fuzzy toys, clothes, or bedding 3
- The American Journal of Respiratory and Critical Care Medicine recommends limiting water exposure; bathing should be supervised with water level no higher than 1-2 inches 3
Common Complications and Management
- The American Journal of Respiratory and Critical Care Medicine recommends preventing skin breakdown by proper skin care and appropriate tube securement 3